EEAgentur.chEEAgentur.ch
EFFEL
The programmeEFFEL for companies
Measures
Standardised measuresNon-standardised measuresFunding check
FAQAbout usContactFunding checkRegister as a utility
ImprintPrivacySitemap
EEAgenturEEAgentur
The programmeEFFEL for companies
Standardised measuresNon-standardised measuresFunding check
FAQAbout usContact
Funding check
EEAgentur

EEAgentur is a service of Energieagentur St.Gallen. We make efficiency measures eligible for the EFFEL programme and match them with electricity suppliers.

energieagentur-sg.ch ↗bfe.admin.ch ↗

Programme

  • The programme
  • EFFEL for companies

Measures

  • Standardised measures
  • Non-standardised measures
  • Funding check
  • Register as a utility

Agency

  • FAQ
  • About us
  • Contact

Legal

  • Imprint
  • Privacy
  • Sitemap
© 2026 Energieagentur St.GallenEFFEL · Efficiency gains through electricity suppliers · Art. 46b EnG
  1. Home
  2. Standardized Measures
  3. ICT
  4. IK-01a

SFOE standard catalogue · ICT · Version 2.0

Replacement of Electronic and ICT Equipment

The goal is to standardize the calculation of electricity savings triggered by the replacement of electronic and ICT devices, taking into account efficiency improvements in devices such as computers, monitors, printers, network equipment and other ICT components.

At a glance

IK-01a

Type
Replacement
Version
2.0
Example A
no example in the catalogue
Proofs
1 documents
Start funding check for IK-01a
  • Requirements
  • Proofs
  • Calculation basics
  • Downloads

Requirements

Only measures that meet the requirements of the Energy Ordinance (SR 730.01; EnV) can be credited. The additional requirements for the technical characteristics and for the implementation of the measure are set out in Table 1.

Device typeOnly the following device types, which fall within the scope of the Energy Efficiency Ordinance (EnEV; SR 730.02), are covered by this measure.
Energy efficiencyThe new devices must have at least the following energy efficiency class / meet the following requirements:
Televisions, screen diagonal ≤ 54''E
Televisions, screen diagonal > 54''D
Monitors, screen diagonal ≤ 27''C
Monitors, screen diagonal > 27''E
LaptopsAusschliesslich als Ersatz eines Desktop-PCs1*

* The measure is invalid if the previous device was also a laptop.

Proof of compliance

Compliance with the requirements must be demonstrated by the following documents. The documents listed in Table 2 are an integral part of the proof of measure implementation.

  1. 1.Invoice documents (PDF, PNG or JPEG format)
Calculation basics: symbols, units and formulasNot needed for the review, useful for recalculating▾

Symbols, Terms and Units

SymbolDescriptionUnit
Eannual electricity consumptionkWh/a
ΔEecocumulative electricity savingskWh
PGerätpower consumption of the deviceW
nnumber of devices-
hBetriebannual operating hoursh/a
fStandbystandby factor-
Nsstandard effective durationa

Calculation Formulas

Jährlicher Stromverbrauch IKT-Gerät

E = n × (PBetrieb × hBetrieb + PStandby × hStandby) / 1000

The annual electricity consumption results from the number of devices multiplied by the sum of operating and standby consumption.

Standby-Stunden

hStandby = 8760 - hBetrieb

The standby hours per year result from the total hours (8760) minus the operating hours.

Annual Electricity Savings

ΔE = Ebefore - Eafter

The annual electricity savings result from the difference between electricity consumption before and after device replacement.

Cumulative Electricity Savings

ΔEeco = ΔE × Ns × f

The cumulative electricity savings result from the annual savings multiplied by the standard effective duration and the correction factor.

Downloads

Documentation (PDF)Complete technical documentation including calculation basisDownload DOC
Excel Calculator (XLSX)Interactive calculation tool for savingsDownload PRO

Previous measure

First in ICT

Next measure

IK-02a · Outsourcing of IT Infrastructure to an External Data Center →

Other measures in ICT

IK-02aOutsourcing of IT Infrastructure to an External Data CenterIK-03aOptimization of UPS Redundancies in Data CentersIK-03bOptimization of Supply Air Temperature in Data Centers

Part of the EFFEL programme

Standardised measures are one of two measure types in the EFFEL programme (efficiency improvements by electricity suppliers, Art. 46b EnG). They follow a predefined SFOE catalogue with fixed savings values.