Measure Goal

The goal is to estimate the electricity savings triggered by the retrofit of a remote control for heating in second homes and holiday apartments.

Examples and Scenarios

5.0 Rp./kWh
0.1 Rp./kWh10.0 Rp./kWh
Scenario C
Savings

Retrofit of a remote control for a decentralized electric heating system in a 2.5-room holiday apartment

4'800
kWh

eligible kWh, accumulated over the measure's lifetime

Funding contribution
CHF 240

Inputs

Zweitwohnung 2 Zimmer (GEAK F)

Requirements

Only measures that meet the requirements of the Energy Ordinance (SR 730.01; EnV) can be credited. The additional requirements for the technical characteristics and for the implementation of the measure are set out in Table 1.

Old systemNew system
TechnologyFixed electric, electric storage and electric underfloor single-room heaters within the scope of Annex 1.18 EnEVFixed reversible split or multi-split air conditioners (maximum 2 outdoor units per building) within the scope of Annex 1.13 EnEV
Building categoryResidential, single-family house
ImplementationThe replacement and commissioning of the new system must be carried out by a qualified specialist or company.

Proof of compliance

Compliance with the requirements must be demonstrated by the following documents. The documents listed in Table 2 are an integral part of the proof of measure implementation.

  • 1.Explanation (PDF format, max. 2 A4 pages) of how it is ensured that the replaced devices were properly disposed of (e.g. by means of declarations, disposal items on contractor invoices, etc.).
  • 2.Invoice documents (PDF, PNG or JPEG format)
  • 3.GEAK building energy certificates or a brief explanation of the CO₂ calculator input data (PDF format)

Would you like to submit your project or need help?

Contact

Symbols, Terms and Units

SymbolDescriptionUnit
Eannual electricity consumptionkWh/a
ΔEecocumulative electricity savingskWh
fPutilization factor—
NsStandard effective durationa

Calculation Formulas

Cumulative Electricity Savings

ΔEeco = (Eold - Enew) × feco × Ns

The cumulative electricity savings result from the difference between the electricity consumption without and with remote control, multiplied by the reduction factor and the standard effective duration.

Annual Electricity Consumption

Ex,i = (fP,i/η_x) × fR × (Qli0 + ΔQli × a) × (1 + (9.4 - θ_e,avg) × 0.06 K⁻¹) × AE

The annual electricity consumption is reduced by the utilization factor, which takes into account the lowering of the room temperature during absence.

Downloads

Documentation (PDF)
Complete technical documentation including calculation basis
Download DOC
Excel Calculator (XLSX)
Interactive calculation tool for savings
Download PRO

Part of the EFFEL programme

Standardised measures are one of two measure types in the EFFEL programme (efficiency improvements by electricity suppliers, Art. 46b EnG). They follow a predefined SFOE catalogue with fixed savings values.

More about the EFFEL programme