Scenario A
Replacement of lighting in an industrial building (10,785 m²)
1'160'000kWh
eligible kWh, accumulated over the measure's lifetime
Funding contributionCHF 58’000
Inputs: Traffic area, Office, Production, Warehouse, Utility room
SFOE standard catalogue · Lighting · Version 2.0
The goal is to standardize the calculation of electricity savings that are triggered by the optimization, replacement or retrofitting of lighting systems or parts thereof (replacement of lamps or luminaires, luminaire conversion and/or installation of additional detection and control components) indoors, taking into account all consumption-relevant parameters.
Examples and Scenarios
Replacement of lighting in an industrial building (10,785 m²)
1'160'000kWh
eligible kWh, accumulated over the measure's lifetime
Funding contributionCHF 58’000
Inputs: Traffic area, Office, Production, Warehouse, Utility room
Replacement of floor lamps in an open-plan office (130 workstations)
227'300kWh
eligible kWh, accumulated over the measure's lifetime
Funding contributionCHF 11’365
Inputs: Open-plan office
Requirements
Only measures that meet the requirements of the Energy Ordinance (SR 730.01; EnV) can be credited. The additional requirements for the technical characteristics and for the implementation of the measure are set out in Table 1.
| Old system | New system | |
|---|---|---|
| Quality verification | - | Minergie limit value according to SIA 387/4:2023 Illuminance no more than 20% above the minimum values according to SN EN 12464-1 |
| Implementation | Planning, installation and commissioning of the new system must be carried out by a qualified specialist / company and metrologically verified after completion. | |
| Disposal | The consumption-relevant components of the old devices may not continue to be operated within Switzerland. Proper disposal or export must be demonstrable on request. | |
Proof of compliance
Compliance with the requirements must be demonstrated by the following documents. The documents listed in Table 2 are an integral part of the proof of measure implementation.
| Symbol | Description | Unit |
|---|---|---|
E | annual electricity consumption | kWh/a |
ΔEeco | cumulative electricity savings | kWh |
f | Factor | — |
Ns | Standard effective duration | a |
Annual Electricity Savings
The annual electricity savings result from the difference between electricity consumption before and after the measure.
Cumulative Electricity Savings
The cumulative electricity savings result from the annual savings multiplied by the standard effective duration and the correction factor.
Lighting Electricity Consumption
The electricity consumption of the lighting is calculated from the sum of area, installed power and operating hours for each room use.