Scenario A
Laundromat replaces six tumble dryers
279'936kWh
eligible kWh, accumulated over the measure's lifetime
Funding contributionCHF 13’997
Inputs: 6x Wäschetrockner bis 9 kg (0.19 kWh/kg neu)
SFOE standard catalogue · Commercial Equipment · Version 2.0
The goal of this document is to estimate the electricity savings triggered by the replacement of commercial laundry drying equipment (tumble dryers or drying cabinets) with energy-efficient models on a flat-rate basis.
Examples and Scenarios
Laundromat replaces six tumble dryers
279'936kWh
eligible kWh, accumulated over the measure's lifetime
Funding contributionCHF 13’997
Inputs: 6x Wäschetrockner bis 9 kg (0.19 kWh/kg neu)
Requirements
Only measures that meet the requirements of the Energy Ordinance (SR 730.01; EnV) can be credited. The additional requirements for the technical characteristics and for the implementation of the measure are set out in Table 1.
| Energy efficiency | The new tumble dryers must not exceed the following electricity consumption values determined according to EN 50594:2018. The new drying cabinets must have a heat pump. |
|---|---|
| Tumble dryers with a load capacity of up to 9 kg laundry | |
| Tumble dryers with a load capacity of 10 - 23 kg laundry | |
| Tumble dryers with a load capacity of 24 - 40 kg laundry | |
| Drying cabinets |
Proof of compliance
Compliance with the requirements must be demonstrated by the following documents. The documents listed in Table 2 are an integral part of the proof of measure implementation.
| Symbol | Description | Unit |
|---|---|---|
e | specific electricity consumption | kWh/kg |
E | annual electricity consumption | kWh/a |
ΔEeco | cumulative electricity savings | kWh |
f | Reduction factor | — |
nw | Usage intensity | kg/a |
Ns | Standard effective duration | a |
Creditable Electricity Savings
The creditable electricity savings result from the difference between the current and new annual electricity consumption, multiplied by the reduction factor (0.75) and the standard effective duration (15 years).
Annual Electricity Consumption
The annual electricity consumption is calculated from the product of the specific electricity consumption and the usage intensity (kg of dried laundry per year).